Introduction
The search for the ideal anterior ceramic material has accelerated, with the increase in the aesthetic expectations of patients in recent years. An ideal aesthetic restoration should be morphologically and optically compatible with the natural teeth and biologically acceptable. All ceramic restorations offer an aesthetic appearance close to the natural optical properties of the tooth structure (1,2). However, it is necessary to provide harmony with the neighboring teeth for a natural appearance, but this desired natural appearance is not always achievable due to difficulties in matching the natural tooth color with the existing tooth porcelains (3,4). Hue, chroma, value, and translucency/opacity are color elements that affect the aesthetics of dental restorations (5,6). The translucency of the restoration is the most important factor in achieving a natural tooth appearance (7-10). Since human enamels have a natural translucency, aesthetic materials must reproduce the translucency of natural teeth (11,12). Especially for younger individuals, aesthetic ceramics must have high translucency in order to mimic the natural tooth structure (13). The translucency parameter (TP) and contrast ratio (CR) are used to measure translucency of dental materials (14). A high TP indicates that the material is less opaque (15). Also, the ceramic materials of fixed dental prostheses must provide long-term color stability to avoid repeated restoration.
The surface finishing affects many aspects of the final restoration, such as staining, the degree of color change, plaque buildup, and the wear resistance of ceramics (16,17). Food and other residues will stick to the surface, if a restoration presents a rough surface. It has been shown that significant color change occurs on rough surfaces (18). The surface cracks that develop during the preparation of the restoration are reduced by the polishing process (19). Therefore a dental restoration should have a highly polished surface due to this aesthetic, mechanical, and biological considerations.
When choosing an all-ceramic system, factors, such as the color of the ceramic material and neighboring teeth and the forces foreseen in that area, should be considered (20,21). For example, the fragile structure of conventional glass ceramics limits the use of these ceramics in the posterior area (22). The use of zirconia as a core material has improved the mechanical properties of all ceramic restorations, but zirconia copings need to be a coated with a ceramic application to attain proper aesthetics (23,24). With the widespread use of dental computer-aided design/computer-aided manufacturing (CAD/CAM) systems, various ceramics offering both durable and optimal aesthetics have been introduced into the dental market. One of these is monolithic glass-ceramics, which was developed to provide aesthetics without the need for coating ceramics (25). Elimination of the connection between the core and the coating ceramic can make the restoration more structurally sound and longer-lasting (26,27). Lithium disilicate ceramic restoration is one of the most popular monolithic ceramic systems for anterior and posterior single crowns and partial veneered restorations because of its favorable physical properties (28). However, the durability of this ceramic in the posterior region may not be optimal (29-31). Recently, zirconia-reinforced lithium silicate glass-ceramics were introduced for inlays, onlays, implant abutments, and partial and full crowns manufactured using the CAD/CAM system. Zirconia particles are included to strengthen the ceramic build (32).
To the best of the authors’ knowledge, no information is available on the clinical and laboratory translucency change of monolithic CAD/CAM ceramics subjected to different surface finishing methods and immersed in coloring solutions, such as cola, coffee, and black tea. Therefore, the aim of this study was to compare the TP of two types of monolithic CAD/CAM ceramics, the Vita Suprinity HT (VS) and the IPS e.max CAD HT (IPS), after three different surface finishing methods and exposure to cola, coffee, and black tea solutions. The null hypothesis was that the type of surface finishing and all colorant solutions would not affect the translucency of the monolithic CAD/CAM ceramics.
Materials and Methods
Preparation of Samples
Two monolithic CAD/CAM ceramics, including a zirconia-reinforced lithium silicate ceramic (VS, Vitazahnfabrik) and a lithium disilicate ceramic (IPS e.max CAD, Ivoclar, Vivadent AG) were evaluated (Table 1).
Ceramic blocks were cut at 150 rpm using a precision cutting machine (Micracut 201, Bursa, Turkey) with a diamond disc to render a sample thickness of 1.2 mm. Both ceramic materials were divided into three main groups and control group (n=40) for the three different surface finishing methods: glaze, sandpaper discs (Sof-lex), and silicone-carbide rubber points (Shofu). After the surface treatments, each group was divided into four subgroups according to the exposed solutions: distilled water (control), cola, coffee, and black tea solutions. A total of 240 specimens were prepared, 10 in each group (n=10). After the blocks were cut, all samples were subjected to the crystallization cycle according to the manufacturer’s instructions. Then, both surfaces of the samples were sanded with 600, 800, and 1.200 grained silicon carbide abrasives (English Abrasives, London, UK) under water cooling at 100 rev/min before surface treatments were applied. Each ceramic material received one coat of glaze according to the manufacturer’s instructions (Vita akzent plus glaze, Vita, Germany and IPS Empress Universal glaze, Ivoclar, Vivadent). For the specimens to be surface treated with Sof-lex, Sof-lex polishing discs (Sof-lex polishing discs, 3M ESPE, St.Paul, ABD) with a diameter of 12.7 mm were used in accordance with the manufacturer’s recommendation. Polishing was first carried out at 10.000 rpm with thick and medium discs, and then followed with thin and super-thin discs. For the specimens to be surface treated with Shofu, first, a white stone (Dura-white Stone, Shofu, Japan), and, then, three silicone-carbide rubber points (Ceramiste Standard, Ultra and Ultra II, Shofu, Japan) were used, respectively, for smoothing the surface. Polishing operations were performed by the same applicator using a low-speed rotary hand tool (Kavo Ewl 4990; KaVo Dental Gmbh, Germany). Sample thicknesses were checked with a digital caliper (Absolute Digimatic, Mitutoyo, Japan). After polishing, all samples were sterilized for 10 s using distilled water in an ultrasonic cleaner (Pro-Sonic 600; Sultan Healthcare, NJ, USA), and then air-dried. The groups were formed by random selection of the ten samples for each group. The groups are shown in Table 2. I1a, I2a, I3a, V1a, V2a, and V3a served as the control groups.
Preparation of Colorant Solutions
Each of colorant solutions were prepared for consumption 5 cups per day. Instant coffee sticks (Nescafe Classic, Nestle, Bursa, Turkey) and tea bags (Earl Grey, Doğuş, Ordu, Turkey) were used in the study and prepared according to the manufacturer’s suggested concentrations. The 18.5 g x5 coffee sticks were added to 1 L of boiled distilled water. To prepare the tea solution, 10 g x5 black tea bags were added to 1 L of boiled water and allowed to steep for 3 min. A one L cola (Coca-Cola, Coca-Cola Co, İstanbul, Turkey) solution was used in the same manner.
Coloring Methods
Distilled water was used for the control group in the study. The samples were stored in cola, coffee, and black tea, distilled water solutions in the incubator at 37±1 °C. As 144 h corresponds to about six months of coffee consumption (33), all sample groups were exposed to the relevant solutions for 144 h to ensure standardization. After removal from the colorant solutions, the samples were washed with distilled water for five min, and then dried.
Color Measurements
Color measurements were performed before and after exposure to the solutions after surface treatments were applied. Color measurements were made with a clinical spectrophotometer (Vita Easy Shade Advance, Vita Zahnfabrik, Germany) using a black and white background under D65 lighting conditions. Translucency values of the samples were determined by the TP according to the CIE L * a * b * system. For the translucency measurement, the formula TP = [(L * B-L * W) 2+ (a * B-a * W) 2+ (b * B-b * W) 2] 1/2 was used. Data’s were statistically analyzed using three-way analysis of variance (ANOVA). The Bonferroni test was used for multiple comparisons. The SPSS (Statistical Package for the Social Sciens) for Windows computer program was used for statistical analyses. Material, method, group and interaction effects were considered to be significant (p<0.001).
Results
The TP values obtained for each group are summarized in Table 3. When a material has a TP of 100, TP is considered transparent; a TP of 0 indicates that the material is opaque. TP shows the color difference (DE*) on a black and white background of a material of the same thickness and is calculated with the color difference formula (14). A color difference equal to zero (DE*=0) describes a non-translucent material with excellent masking properties (34).
Material, method, group and interaction effects were found statistically significant (p<0.001). There was a statistically significant difference in Total TP value between the materials in terms of applied surface treatments (p<0.05). The ranking of the TP values of materials for control group after the surface finishing process from highest to lowest was Sof-lex > Glaze = Shofu for IPS and Shofu > Sof-lex > Glaze for VS. After surface finishing, the Total TP value of the VS material (17.18±2.63) was found to be higher than that of the IPS material (15.55±1.93). The ranking of the Total TP values after the surface finishing process from highest to lowest was Sof-lex > Glaze > Shofu for IPS and Shofu > Glaze > Sof-lex for VS. The TP value for each group was different in terms of exposed solutions after surface finishing (p<0.05). The highest TP value was demonstrated by the VS control group treated with Shofu (V3a) (TP: 21.36±0.07). The lowest translucency value was found in the VS group treated with Sof-Lex and exposed to black tea (V2c) (TP: 11.76±0.07). The translucency value of each material was generally statistically significant in terms of exposed solutions after the applied surface treatment (p<0.05). The greatest decrease in TP values was observed in the IPS groups incubated in the cola solution. There was a statistically significant difference in TP values after exposure to colorant solutions for both materials (p<0.05). The lowest TP value for the IPS group was observed in the samples exposed to cola, while, for the VS group, it was observed in the samples exposed to black tea.
Discussion
Based on the results of our work, the null hypotheses were rejected as the translucency of the monolithic CAD/CAM ceramics was affected by surface finishing and colorant solutions. Significant differences were shown among the ceramic groups for TP value.
Translucency is a very important factor in the selection of metal-free materials. Translucency is usually determined by CR or TP. Color determination in dentistry is done visually or instrumentally using spectrophotometers and colorimeters (35). Color measurements made with instruments indicate the potential to eliminate subjective errors in color evaluation and more importantly, are more sensitive when compared to the naked eye, without measuring the slight differences between the colors of colored objects on flat surfaces (36). During color measurement, both the true color of the surface and the lighting condition where the surface is measured affect the color that is measured (33). Therefore standard illuminant D65 was used in the study.
Color stability is as important as translucency in the long-term clinical success of ceramic restorations. Since researchers focus on the mechanical properties of ceramics, little is known about the color changes which occur over time in ceramic restorations. The absorption of colorants from external sources could cause staining in dental materials (37). Several studies have shown that nicotine (38), coffee and tea (39) were coloring solutions for polymeric materials. However, there is little research showing the effects of these liquids on ceramic surfaces. Surface roughness and surface finishing method have been shown to affect the paint ability of dental materials (37). Surface roughness has a direct effect on the sensitivity of the material to the extrinsic stain. However, finishing and polishing procedures, as well as the composition of the dental material, can affect the surface quality of the material; premature coloration is thought to be due to this (40). The purpose of this study was to observe the translucency change in monolithic glass ceramics exposed to cola, coffee, and black tea for six months. The effect of various surface finishing methods on the translucency of ceramics was also investigated.
Dental restorations should have a highly polished surface prior to use. If there is a rough surface on a restoration or prosthesis, food and other residues will stick to the rough surface. The ceramic surface is traditionally subjected to a surface treatment known as glaze. The glaze process closes the open pores on the surface after firing, providing better optical properties and more surface smoothness (41). At the same time, a smooth surface is formed to reduce biofilm accumulation (41). However, direct finishing and polishing methods on the restoration surface are widely used intraorally. Abrasive rubbers, aluminum oxide discs or diamond polishing paste combined with felt and silicone rubber discs can be used for this process. This procedure produces smooth surfaces, shortens the working time, and can be used to restore brightness after glaze processing, giving the restoration a more natural appearance (42). However, studies are lacking on the best finishing and polishing methods for VS and IPS ceramics to obtain a uniform ceramic surface. The Shofu abrasive tire system consists of ceramic polishing lacquer for pre-polishing, ultra for polishing, and ultra II for a high gloss finish. Sof-lex discs are aluminum oxide discs. Polishing using small to large discs is performed. In our study, the groups which were finished with Sof-lex for IPS ceramics and were finished with Shofu for VS ceramics showed the highest TP values. The difference in the TP values could be the result of the different dimensions of the ceramic material crystals. At the same time, the distribution of crystals and the hardness of the material could affect the TP.
According to our results, statistically different TP values were determined for the different groups. The TP values of the ceramics ranged from 11.76 (V3b) to 21.36 (V1c). It was found that the TP value for the controls of the total VS material after surface treatment was higher than that of the controls of the total IPS material. Few studies have reported the TP values of the monolithic ceramics used in this study. In the present study, it was found that the TP value of the zirconia-reinforced glass-ceramic was higher than that of the lithium disilicate ceramic, similar to the findings of Awad et al. (43) and Sen and Us (44) studies. The researchers attributed this transparency difference to the fact that the lithium disilicate crystals in the lithium disilicate were four to eight times larger than those in the zirconium-reinforced glass-ceramics (43,44). It has been reported that smaller crystals in the zirconia-reinforced lithium silicate glassy matrix of the ceramic exhibit better TP values due to the high glass content (43). In light of this information, we think that differences in TP values are responsible for the crystal content, grain size and microstructural differences in the materials.
To the best of the authors’ knowledge, there is no study evaluating the TP of the specific ceramics used in our study after being kept in colorant solutions. The results of Ramakrishnaiah et al. (45) study showed an increase in the surface wettability and surface roughness of VS and IPS ceramics in direct proportion to the hydrofluoric acid etching time. In this study, generally the translucency value decreased in the groups treated with cola, coffee, and black tea for both VS and IPS groups according to the control groups. The lowest TP value for the IPS group was observed in the samples exposed to cola, while for the VS group it was observed in the samples exposed to tea. Cola, tea and coffee are acidic liquids (46). It is thought that this decrease in translucency may be because of the increased wettability of the ceramics as a result of the increase in the roughness of the ceramics due to the acidic effects of cola, coffee, and black tea. al-Hiyasat et al. (47) reported that cola abrades various ceramics and that this erosion can lead to a tribochemical corrosion mechanism. Crispin and Caputo (18) have shown that significant color change occurs on rough surfaces. The decrease in TP values after treatment with cola, coffee, and black tea indicates that these solutions cause color change on the VS and IPS ceramics. It is reported that theaflavins in tea leaves cause color change. Likewise, caffeine and caffeic acid cause a color change in the materials (48).
Study Limitation
One limitation of this study is that the investigation was carried out under in vitro conditions. Further in vivo studies are required to simulate clinical conditions for TP of VS and IPS ceramics.
Conclusions
Within the limitations of this study, the following conclusions were drawn. The translucency was affected according the monolithic CAD/CAM ceramic type. The translucency of the zirconia-reinforced glass-ceramic was found to be higher than that of the lithium disilicate glass-ceramic. Colorant solutions decreased the translucency of both VS and IPS ceramics. The lowest TP value for the IPS group was observed in the samples exposed to cola, while, for the VS group, it was observed in the samples exposed to black tea. According to the results of this study, IPS ceramics finished with Sof-Lex and VS ceramics finished with Shofu exhibited higher translucency values.
Ethics
Ethics Committee Approval: The ethics committee approval was not necessary since the study was in vitro.
Informed Consent: This study is a laboratory study. Therefore, patient consent is not required.
Peer-review: Externally peer-reviewed
Authorship Contributions
Concept: Y.H., I.S., Design: Y.H., I.S., Data Collection or Processing: Y.H., I.S., Analysis or Interpretation: Y.H., I.S., Literature Search: Y.H., Writing: Y.H.
Conflict of Interest: No conflict of interest was declared by the authors.
Financial Disclosure: The authors declared that this study received no financial support.